Menu
Soporte
Biblioteca Técnica

Biblioteca Técnica

La biblioteca técnica de Megger ofrece acceso a una amplia gama de contenidos y recursos, tales como guías técnicas, notas aplicativas y mucho más. Cuando usted se registra y crea una cuenta Megger, usted podrá entre otras cosas, registrar su producto y tener acceso a una amplia gama de actualizaciones de software y descarga para su productos.

Filtrar por aplicación
    Mostrando artículo/s 1 - 10 de 293 en total
Testing frequency relays with SVERKER900 considering the IEC 60255-181 standard
This application note is more than a description of how to use SVERKER 900 for testing frequency relays. It also wantsto spread the knowledge about IEC standardization in relay protection. Many engineers often associate theIEC series of protection standards IEC 60255-1xx1to relay type testing, and believe that they do not need to have competence about this series of standards. This is a misunderstanding: many of the concepts, definitions and test procedures described in thestandards are there to be used in relay technique, no matter if the role is relay manufacturer, user, or commissioning / maintenance testing engineer ([2], [3]).
Publicado: 30 julio 2020
Descargar PDF
DLRO2: long test lead test mode
When measuring very low resistance the four-wire test method has for many years been the standard method. The main advantage being that it simply and easily removes the resistance of the test leads from the measurement. However, what happens when those test leads need to be verylong?
Publicado: 27 julio 2020
Descargar PDF
DLRO2: new difference meter
Introducing the first low resistance ohmmeter to feature a difference meter, a device that turns changes in resistance into a moving pointer and percentage change. When testing multiple similar connections, it makes it easy to spot those small increases in resistance that eventually turn into major faults.
Publicado: 27 julio 2020
Descargar PDF
PowerDB Software
Software download files for PowerDB
Publicado: 14 julio 2020
Descargar
SmartFuse 250
Software for the SmartFuse 250
Publicado: 16 junio 2020
Descargar
Transformer winding resistance measurement: field challenges
Megger’s article “Transformer Winding Resistance Measurement: Field Challenges” was presented at the 2020 NETA PowerTest Conference in Chicago, Il. This article takes an in-depth look at the lesser known facts associated with the DC winding resistance (WR) measurements, diving deeper into topics such as selection of the correct test current, and the importance of compliance voltage during the test. Phenomena as core saturation, current stabilization, the influence of winding inductance on readings, and the effect of temperature, are also explained.
Publicado: 12 junio 2020
Descargar PDF
VLF Sinus 62 Firmware
VLF Sinus 62 Firmware
Publicado: 9 junio 2020
Descargar
VLF Sinus 45 Firmware
VLF Sinus 45 Firmware
Publicado: 9 junio 2020
Descargar
SVERKER
Software download files for SVERKER900
Publicado: 4 junio 2020
Descargar
Transformer turns ratio test: some unknown facts
Transformer Turns Ratio (TTR) is one of the most common test used to assess the condition of the transformer’s windings and core.  It is performed as a part of acceptance and maintenance test procedure to determine any problems due to poor design, assembly, handling, overloading, fault conditions or poor maintenance. TTR results are compared against the nameplate ratings to determine any possible insulation deterioration, shorted turns, core heating or any other winding or core abnormalities.TTR is a simple and easy test to perform that is often taken for granted without fully understanding the principle and basis of the test. In cases when measurements are not within expected limits, it becomes a challenging task to determine the root cause and resolve the problem. This paper will focus on some of the unknown facts associated with the TTR test. The paper covers in detail the effect of applied test voltage, comparative analysis of step up vs step down excitation, different vector configurations, differences between nameplate ratio, voltage ratio and turns ratio, sources of ratio and phase angle errors, comparison of per phase testing vs true three phase testing, extreme tap ratios being out of tolerance for On Load Tap Changers (OLTC), and TTR test correlation with other electrical tests. The paper also provides field test results and case examples to explain the above-mentioned unknown facts.
Publicado: 28 abril 2020
Descargar PDF Leer el artículo completo
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • >
  • Mostrando artículo/s 1 - 10 de 293 en total